314   Advanced Design Examples of Seismic Retrofit of Structures



              TABLE 5.14 Plastic Hinges in the Braces of the Sports Building (Refer to
              Fig. 5.10)
              Brace              a      b      c       IO       LS     CP
              Compressive brace  0.5    8      0.2     0.25     3      4
              Tensile brace      11     14     0.8     0.25     7      9




                       DL= 3944 (kg)   DL= 2139 (kg)   DL= 3967 (kg)
                       LL= 1277.5 (kg)   LL= 1825 (kg)   LL= 1277.5 (kg)
                         6.0 (m)         3.0 (m)        6.10 (m)




              M CE ¼ Z:F ye ¼ 8:3 10  4   23600 ¼ 19:58ton   m   M demand ¼ 13:24ton   m
              V CE ¼ 1:5F v A W ¼ 1:5 0:4 23600  2 0:87 19:2ð  Þ 10  4  ¼ 47:3ton
                V demand ¼ 14:47ton

               It is concluded that all the beams having cradle-type connections satisfy the
            requirements of acceptance criteria and are not vulnerable.



            5.8.2 Columns

            The results of the controls of the columns in the main and sports buildings are
            presented in Tables 5.16 and 5.17, respectively. As can be seen, there are few
            columns that do not pass the acceptance criteria for the columns and are hence
            classified as vulnerable.



            5.8.3 Infill Walls

            Control of the infill walls in the main building is made in Table 5.18. Based on
            this table, there are several vulnerable infill walls. Examples of the plastic
            hinges formation in the main building are shown in Figs. 5.12 and 5.13. The
            results of the nonlinear static analysis are presented in Table 5.19.



            5.8.4 Upper and Lower Truss Ridges

            Control of the upper and lower truss ridges in the sports building is shown in
            Table 5.20.