Page 248 - Advances in Forensic Applications of Mass Spectrometry - Jehuda Yinon
P. 248

1522_book.fm  Page 221  Thursday, November 13, 2003  9:58 AM









                             kCount                                          file5807.ms RIC
                               15
                                                          GC/MS
                               12                                                 Would be Negative
                               10
                                7
                                5
                                2
                             kCount                                           f5808ms2.ms RIC
                                2                        GC/MS/MS
                                2
                                1
                                1
                                5
                                0
                                    1     2      3     4     5      6     7      8     9      10
                                                                                            minute
                             Figure 5.25  Upper TIC: tin can sample by GC/MS; bottom TIC: tin can sample
                             by GC/MS/MS.





                                                            C3 - BENZENES
                             kCount
                                1.5  Sample - GC/MS
                                1.2
                                1.0
                                0.7  Would be Negative
                                0.5
                                0.2
                                0.0
                             MCount                                            May indicate an ignitable liquid
                                2.5  Gasoline - GC/MS
                                2.0                                            Good candidate for GC/MS/MS
                                1.5
                                1.0
                                0.5
                                0.0
                             kCount
                                7.5  Sample - GC/MS/MS
                                5.0  Now Positive
                                2.5
                                0.0
                             kCount
                                 6  Gasoline - GC/MS/MS
                                 5                                              Excellent comparison
                                 4
                                 3
                                 2
                                 1
                                 0
                                       1     2     3     4     5     6     7     8     9  minute
                             Figure 5.26  GC/MS/MS improves comparability to the reference gasoline anal-
                             ysis over GC/MS.