Page 68 - Advances in Renewable Energies and Power Technologies
P. 68
5. The PV Arrays 41
FIGURE 1.35
Solar array with back-connected bypass protection diodes.
function. It conducts the current of the string and prevents the interruption of the cur-
rent in case of complete cell shadowing or cracking of the interconnect wires or
cells.
5.4 MEASUREMENT DATA AND PRACTICAL CONSIDERATIONS
Fig. 1.36 shows the IeV characteristics of a solar module consisting of n e ¼ 36,
2
n s ¼ 6 array solar cells of 2 cm 2 cm measured at AM ¼ 100 mW/cm at two
different temperatures.
It is clear from this figure, that the shape of the IeV curve of the array is similar
to that of a single solar cell as predicted by the previous analysis of the module
FIGURE 1.36
The IeV characteristics of a solar cell module at different temperatures.