Page 377 - Air Pollution Control Engineering
P. 377

08_chap_wang.qxd  05/05/2004  4:26 pm  Page 353
                    Thermal Oxidation                                                         353
























































                       Fig. 3. Flowchart for categorization of a waste gas to determine its suitability for incineration
                    and need for auxiliary fuel and air.


                    of values are shown in the table: one set for nonhalogenated emission streams and
                    another set for halogenated emission streams. The combustion temperature and resi-
                    dence time values listed are conservative and assume adequate mixing of gases in the
                    incinerator and adequate oxygen in the combustion chamber. The criteria in Table 3 are
                    not the only conditions required for achieving the specified destruction efficiencies. For
                    a given destruction efficiency, HAP emission streams may be incinerated at lower tem-
                    peratures with longer residence times. However, the values provided in Table 3 reflect
                    temperatures and residence times found in industrial applications. Based on the required
   372   373   374   375   376   377   378   379   380   381   382