Page 268 - 05. Subyek Teknik Mesin - Automobile Mechanical and Electrical Systems Automotive Technology Vehicle Maintenance and Repair (Vehicle Maintenance Repr Nv2) by Tom Denton
P. 268

2
      252                                 Automobile mechanical and electrical systems

























                                          Figure 2.341       The core or rotor is made of very strong rare earth metal permanent magnets


























                                          Figure 2.342       High-voltage battery power switch


                                          As already mentioned, any person with a heart pacemaker or any other
                            Safety fi rst
                                        electronic medical device should not work on the IMA system. The magnetic
              Any person with a heart pacemaker   fi elds present ( Fig. 2.341   ) can affect these devices and therefore present a
      or any other electronic medical   very signifi cant danger. The use of any magnetic storage media near the IMA
      device should not work on the IMA   system should be avoided. In the presence of the system’s strong magnetic
      system because of the high-strength
      magnetic fi elds.                  fi eld, data could be partially or totally erased. A mechanical or electronic
                                        wristwatch would also be damaged.
                                          Before maintenance:

                                                  Turn OFF the ignition switch and remove the key.
                                        ●
                                                Switch OFF the battery module switch ( Fig. 2.342   ).
                                        ●
                                                Wait for 5 minutes before performing any maintenance procedures on the
                                        ●
                                          system. This allows the large storage capacitors to be discharged.
                                                Make sure that the junction board terminal voltage is nearly 0     V.
                                        ●
                            Safety fi rst
                                              During maintenance:
              Electrical safety gloves are NOT the
                                        ●
      same as general working gloves.                Always wear insulating gloves ( Fig. 2.343   ).
                                                Always use insulated tools when performing service procedures to the high-
                                        ●
                                          voltage system. This precaution will prevent accidental short-circuits.
   263   264   265   266   267   268   269   270   271   272   273