Page 156 - Biomass Gasification, Pyrolysis And Torrefaction Practical Design and Theory
P. 156

Chapter | 4  Torrefaction                                    133


                Input Parameter:
                  Capacity of the torrefier 5 W t kg/s of torrefied wood including ash and
                  moisture
                  Desired mass yield 5 MY daf
                  Moisture fraction of raw biomass 5 M
                  Ash fraction of raw biomass 5 ASH
                  Corresponding values of the torrefied product are M and ASH .
                                                             0
                                                                     0
             Mass and Energy Balance
             For the given capacity, W t , of the unit, we calculate the required feed rate of
             raw biomass, W f , entering the drier, and the flow-rate of dried biomass W d
             entering the torrefier section.
                From Eq. (4.1), the flow-rate of the torrefied product on dry ash free
             basis is
                                              0
                                       0
                        W t;daf 5 W t ð1 2 M   ASH Þ 5 MY daf 3 W daf kg=s
             where W daf 5 W f (1 2 M 2 ASH)
                Combining the above two, we get the feed rate of raw biomass as:

                                             0     0
                                     W t ð1 2 M 2 ASH Þ
                               W f 5                  kg=s             (4.17)
                                    MY daf ð1 2 M 2 ASHÞ
                Moisture in the biomass is reduced through torrefaction, but that is not
             the case for ash. Its absolute amount remains unchanged after torrefaction.
             Neglecting any loss of ash between the units, we get:
                                     W t ASH 5 W f ASH                 (4.18)
                                           0
                For further analysis, we consider a single integrated torrefaction system
             as shown in Figure 4.11 where each zone requires specific amounts of heat.

               Example 4.4
               Design a moving bed torrefier to produce 1 ton/h (daf) of torrefied biomass from
               raw biomass containing 30% moisture but negligible amount of ash.
               Torrefaction at 280 C yields 70% mass (daf). Biomass and air enter the unit at

               ambient temperature of 20 C. Hot gas leaves torrefier at 105 C.


               Solution
               Desired output on daf basis:
                              W t 5 1TPH 5 1000=3600 5 0:277 kg=s
                 Moisture in raw feed 5 30%
                 Using Eq. (4.17), we calculate the feed rate of raw biomass (neglecting
               any loss):
                  W f 5 ððW t =MY daf ð1 2 M 2 AÞÞÞ 5 ½0:277=ð0:7 3 ð1 2 0:3Þފ 5 0:566 kg=s
                 Moisture in biomass: W v 5 0.566 3 0.3 5 0.17 kg/s
   151   152   153   154   155   156   157   158   159   160   161