CHAPTER 6                       APPLICATIONS OF BRIDGE DESIGN AND RATING METHODS            257



            Non-composite section (positive and negative fl exure):
        1. Applicable to I section.
        2. Strength limit states I and II.
        3. Construction limit state and uncured slab.
        4. Refer to Section 6.10.5.2.3.
            Non-composite non-compact section (positive and negative fl exure):

        1. Strength limit states I and II.
        2. Construction limit state and uncured slab.
        3. Refer to Sections 6.10.5.3.2 and 6.10.5.3.3.

        6.5.3  Unfactored Dead and Live Load Moments with Impact
            Multi-girder bridge span of 80 ft: Four steel plate girders @ 250 lbs/ft wt., spaced at 10.33
        ft centers, slab thickness of 7 in and 3 in haunch, superimposed dl 3 2.0 kips/ft,
                                           4
            DL moment of inertia, I 3 24,416 in , y  3 19 in
                                              b
                                            4
            SDl moment of inertia, I 3 46,613 in , y  3 29.7 in
                                              b
                        4
            I 3 67,576 in , y  3 39.79 in
                          b
            DL on interior girder:
        1. Slab 0.15k/cft 8 10.33 ft 8 0.58 ft 3 0.9 k/ft
        2. Haunch 0.15 8 1.33 ft 8 0.25 ft 3 0.05 k/ft
        3. Girder 0.25 k/ft 4 0.03 k/ft (for stiff. and diaphragm) 3 0.28 k/ft
            Total DL 3 1.23 k/ft
                            2
            Mdl 3 1.23 8 (80) /8 3 984 k-ft
                               2
            Msdl 3 (2.0/4) 8 (80) /8 3 418 k-ft
            Live load of HS-20 acting on single 80 ft span, Ml 3 582.4 kip-ft, impact factor 3 0.244
            M (L 4 I) 3 1.244 8 582.4 8 1.88 3 1362 kip-ft


        6.5.4  Buckling Capacity Rating of Steel Girders for Load Combinations
            (Summary of steps refer to LRFD sections)
            Non-compact section compression fl ange buckling:
        1. Strength limit states I and II.
        2. Construction limit state and uncured slab.
        3. Refer to Section 6.10.5.3.3c and LRFD Eq. 6.10.5.3.3c

            Non-composite non-compact section lateral torsional buckling:
        1. Positive and negative fl exure.
        2. Strength limit states I and II.
        3. Construction limit state and uncured slab.
        4. Refer to Sections 6.10.5.5 and 6.10.6.4.
        5. L   1.76 r  (E/F ) 1/2
             b        1    yc