24    Centrifugal Pumps: Design and Application

          If a new pump has the same specific speed (N s) as the model but is to
        run at a different rotating speed, head, and flow, the new pump perfor-
        mance will be related to the model by:











        Example

            A new pump is required for 750 GPM, 600-ft head, operating at
          5,000 RPM. The calculated specific speed is 1,100. The model chosen
          is shown in Figure 2-1, peaks at 500 GPM, 300 ft, and operates at
          3,550 RPM. Specific speed = 1,100.

            From Equation 2-1:












            Performance at 5,(XX) RPM can be calculated by applying the fol-
          lowing factors to the 3,550 RPM performance,
           From Equation 2-1:









           From Equation 2-2:
   33   34   35   36   37   38   39   40   41   42   43