Page 43 - Centrifugal Pumps 2E
P. 43

Impeller Design   29
































                   Figure 3-1. Required performance of new pump.

         Step 2: Select vane number and discharge angle.
          The desired head rise from BEP to zero GPM is 20% continuously
        rising (Figure 3-1). To produce this head rise, the impeller should be
        designed with six equally spaced vanes having a 25° discharge angle
        (Figure 3-2).

        Step 3: Calculate impeller diameter.

          From Figure 3-3:
   38   39   40   41   42   43   44   45   46   47   48