Page 41 - Centrifugal Pumps 2E
P. 41
Specific Speed and Modeling Laws 27
Pumps selected as models must have reliable hydraulic performance
based on accurate instrumentation. Unreliable model tests used as a basis
for new development will lead to total disaster. It is strongly suggested
that the selected model pump be retested to verify its hydraulic perfor-
mance.
In the following chapters of this book "specific speed" will be referred