144    Centrifugal Pumps: Design and Application



































             Figure 10-5. Pump performance for initial and ultimate condition.




           Another method of satisfying two capacities at optimum efficiency is
         the installation of volute inserts. These removable pieces reduce the in-
         ternal fluid passages and physically convert a high-capacity pump to low
         capacity (Figures 10-9 and 10-10). Inserts of this type are ideal for low-
         capacity field testing or reduced throughput operation with improved ef-
         ficiency (Figures 10-11 and 10-12).
         Destaging


          It is not unusual for pipelines to start up at low pressure then later
         change to high pressure at constant throughput. This change in pump
        head requirements can be suitably handled by selecting a multi-stage
        pump for the ultimate high-pressure condition. For the initial low-pres-
        sure condition, appropriate impellers are removed and the interstage
        chambers isolated by destaging tubes (Figure 10-13). When changing to
        high pressure the destaging tubes are removed and additional impellers
        installed (Figure 10-14).