Page 279 - Centrifugal Pumps Design and Application
P. 279

248     Centrifugal Pumps: Design and Application

        ure 14-2), In general, many users find that HPRT's repay their capital
        cost within one to two years. However, before hydraulic power recovery
        can be feasible and economical, there must be sufficient flowing liquid
        capacity available at the necessary differential pressure as well as accept-
        able conditions of corrosion and erosion.

                                Selection Process

          Before selecting HPRT's the following information is needed:
           1. Available head range
           2. Available capacity range
           3. Back pressure at turbine outlet
           4. Desired RPM
           5. Chemical composition of the fluid
           6. Temperature and specific gravity of the fluid at turbine inlet
           7. Compressibility of the fluid
           8. Gas entrapment
           9. Preferable materials
          10. Installation configuration
          11. Vibration and noise level
          12. Control equipment































        Figure 14*2. HPRT application range chart (from McCIaskey and Lundquist).