Page 286 - Centrifugal Pumps Design and Application
P. 286

Hydraulic Power Recovery Turbines   255


































                      INPUT DATA FILE NAME:
                     BOOKP
                      14x16x26   HT HSA
                      IMPELLER NO. 1     NO. OF STAGES 1
                      VOLUTE DRG. 6685 IMPELLER DRG.       7131
                      NOZZLE AREA 23.00 VORTEX DIST. 30.00
                      TURBINE RPM= 1170
                     ****************************************
                          GPM      HEAD       BMP    EFF.
                      TOTAL TURBINE PERFORMANCE
                         3000     163.1      -8.8 -7.1
                         4000     173.7      38.6 22.0
                         6000     211.2 198.9 62.1
                         8000     270.7     446.0 81.5
                        10000     352.0     779.5 87.7
                        11000     400.9    978.5     87.9
                        11500     427.4   1086.0    87.5
                        12000     455.3   1198.9 86.9
                        13000     515.1 1440.6      85.2
        Figure 14-5. A computed-vs.-test HPRT performance (courtesy of Bingham-Wif-
        lamette Company).