184                                                      Chapter 4

           Table 4.8 Continued

           3. Calculate the coolant exit temperature, fe, from Equation 4.7.6.

           4. Calculate the logarithmic-mean temperature difference,  (At)i_M. from Equation
           4.7.5.

           5. Calculate the logarithmic-mean temperature-difference correction factor, F,
           from Equation 4.7.4.

           6. Calculate the overall heat-transfer coefficient, U 0, from Equation 4.7.3.
           7. Calculate the clean overall heat-transfer coefficient,  Doc, from Equation 4.7.11.

           8. Calculate the available fouling resistance, R OA, from Equation 4.7.10 and the
           require fouling resistance, R OR, from Equation 4.7.9.

           9.  If  ROA ^ ROR, the condenser will be adequate for the  process.




           NOMENCLATURE

           English

           A       surface  area
                   outside surface  area of a tube
           A 0
           Cc      capital cost per unit area

           CM     maintenance cost per unit area
           Cp     heat capacity at constant pressure
                   total cost
           C T
           C w     cost of water per unit mass
           D       tube diameter
           F      logarithmic mean temperature correction factor or degrees of freedom
           h      heat transfer  coefficient  or enthalpy

           k      thermal conductivity
           m      mass flow rate
           Q      heat transfer rate