Page 275 - Civil Engineering Formulas
P. 275

BUILDING AND STRUCTURES FORMULAS        209

                                        (a)   (b)  (c)  (d)  (e)  (f)




              Buckled shape of column
              is shown by dashed line




              Theoretical K value       0.5   0.7  1.0  1.0  2.0  2.0
              Recommended design value when  0.65  0.80  1.2  1.0  2.10  2.0
              ideal conditions are approximated
                                             Rotation fixed and translation fixed
                                             Rotation free and translation fixed
              End condition
                                             Rotation fixed and translation free
                                             Rotation free and translation free

             FIGURE 9.1 Values of effective-length factor K for columns.

             LOAD-AND-RESISTANCE FACTOR
             DESIGN FOR BUILDING COLUMNS

             Plastic analysis of prismatic compression members in buildings is permitted if
              Fy (l/r)  does not exceed 800 and F   65 ksi (448 MPa). For axially loaded
                                        u
             members with b/t    , the maximum load P , ksi (MPa   6.894   ksi), may be
                             r
                                             u
             computed from
                                    P u   0.85A g F cr             (9.7)
             where A   gross cross-sectional area of the member
                   g

                  F   0.658 F for    2.25
                            y
                   cr
                      0.877 F /  for  	 2.25
                            y
                           2
                      (Kl/r) (F /286,220)
                             y
             The AISC specification for LRFD presents formulas for designing members
             with slender elements.
             ALLOWABLE-STRESS DESIGN FOR BUILDING BEAMS
             The maximum fiber stress in bending for laterally supported beams and girders
             is F   0.66F if they are compact, except for hybrid girders and members with
                b      y
             yield points exceeding 65 ksi (448.1 MPa).  F   0.60F for noncompact
                                                 b       y
   270   271   272   273   274   275   276   277   278   279   280