Page 278 - Civil Engineering Formulas
P. 278

212                    CHAPTER NINE

             For I-shaped beams, symmetrical about both the major and the minor axis or
           symmetrical about the minor axis but with the compression flange larger than
           the tension flange, including hybrid girders, loaded in the plane of the web:

                                 3600   2200(M 1 /Mp)
                            L pd                  r y           (9.17)
                                        F yc
           where F   minimum yield stress of compression flange, ksi (MPa)
                 yc
                M   smaller of the moments, in kip (mm MPa) at the ends of the
                  1
                     unbraced length of beam
                M   plastic moment, in kip (mm MPa)
                  p
                 r   radius of gyration, in (mm), about minor axis
                  y
           The plastic moment M equals F Z for homogeneous sections, where Z   plas-
                           p
                                  y
                      3
                           3
           tic modulus, in (mm ); and for hybrid girders, it may be computed from the
           fully plastic distribution. M /M is positive for beams with reverse curvature.
                               1
                                 p
             For solid rectangular bars and symmetrical box beams:
                             5000   3000(M 1 /Mp)     ry
                        L pd                 r y   3000         (9.18)
                                    F y               F y
             The flexural design strength 0.90M is determined by the limit state of lateral-
                                      n
           torsional buckling and should be calculated for the region of the last hinge to
           form and for regions not adjacent to a plastic hinge. The specification gives for-
           mulas for M that depend on the geometry of the section and the bracing pro-
                    n
           vided for the compression flange.
             For compact sections bent about the major axis, for example, M depends on
                                                           n
           the following unbraced lengths:
              L   the distance, in (mm), between points braced against lateral displace-
               b
                  ment of the compression flange or between points braced to prevent
                  twist
              L   limiting laterally unbraced length, in (mm), for full plastic-bending
               p
                  capacity
                  300r y /  F yf  for I shapes and channels
                  3750(r y /M p )/ JA  for solid rectangular bars and box beams
             F    flange yield stress, ksi (MPa)
              yf
                                     4
                                4
              J   torsional constant, in (mm ) (see AISC “Manual of Steel Construction”
                  on LRFD)
                                  2
                                      2
              A   cross-sectional area, in (mm )
             L   limiting laterally unbraced length, in (mm), for inelastic lateral buckling
              r
             For I-shaped beams symmetrical about the major or the minor axis, or sym-
           metrical about the minor axis with the compression flange larger than the ten-
           sion flange and channels loaded in the plane of the web:
                          L r    r y x 1  2 1    1   X 2 F L 2  (9.19)
                               F yw   F r
   273   274   275   276   277   278   279   280   281   282   283