Page 315 - Civil Engineering Formulas
P. 315

CHAPTER 10
                            BRIDGE AND

                           SUSPENSION-

                      CABLE FORMULAS











             SHEAR STRENGTH DESIGN FOR BRIDGES

             Based on the American Association of State Highway and Transportation Offi-
             cials (AASHTO) specifications for load-factor design (LFD), the shear capacity,
             kip (kN), may be computed from

                                   V u   0.58F y ht w C           (10.1)

             for flexural members with unstiffened webs with h/t  150 or for girders with
                                                   w
                                                  2
             stiffened webs but a/h exceeding 3 or 67,600(h/t ) :
                                                w
                        C   1.0         when    h
                                               t w
                                                   h
                                        when           1.25
                            h/t w                 t w
                             45,000k     when    h
                                                 	 1.25
                            F y (h/t w ) 2     t w
                                                                   2
             For girders with transverse stiffeners and a/h less than 3 and 67,600(h/t ) , the
                                                                 w
             shear capacity is given by
                          V u   0.58F y dt w  C    1   C  2       (10.2)
                                           1.15  1   (a/h)
             Stiffeners are required when the shear exceeds V .
                                                u
               Refer to Chap. 9, “Building and Structures Formulas,” for symbols used in
             the preceding equations.




                                        249