Page 328 - Civil Engineering Formulas
P. 328

BRIDGE AND SUSPENSION-CABLE FORMULAS      261

                          TABLE 10.5 Ratio of Moduli of Elasticity of
                          Steel and Concrete for Bridges

                             f c    for           n    E s
                            concrete                  E c
                             2.0–2.3                11
                             2.4–2.8                10
                             2.9–3.5                9
                             3.6–4.5                8
                             4.6–5.9                7
                           6.0 and over             6




             where w   channel length, in (mm), in transverse direction on girder flange; and
                  B   cyclic variable   4.0 for 100,000 cycles, 3.0 for 500,000 cycles, 2.4
                     for 2 million cycles, and 2.1 for over 2 million cycles.
               For welded studs (with height/diameter ratio H/d   4):
                                      Z r   d  2                 (10.47)

             where d   stud diameter, in (mm); and
                     cyclic variable   13.0 for 100,000 cycles, 10.6 for 500,000 cycles,
                     7.85 for 2 million cycles, and 5.5 for over 2 million cycles.
               Required pitch of shear connectors is determined by dividing the allowable
             range of horizontal shear of all connectors at one section Z , kip (kN), by the
                                                         r
             horizontal range of shear S , kip per linear in (kN per linear mm).
                                r


             NUMBER OF CONNECTORS IN BRIDGES

             The ultimate strength of the shear connectors is checked by computation of the
             number of connectors required from
                                           P
                                      N                          (10.48)
                                           S u

             where N   number of shear connectors between maximum positive moment and
                      end supports
                  S   ultimate shear connector strength, kip (kN) [see Eqs. (10.1) and (10.2)
                   u
                      that follow and AASHTO data]
                     reduction factor   0.85
                  P   force in slab, kip (kN)
   323   324   325   326   327   328   329   330   331   332   333