Page 329 - Civil Engineering Formulas
P. 329

262                     CHAPTER TEN

             At points of maximum positive moments,  P is the smaller of  P and P ,
                                                              1
                                                                   2
           computed from
                                                               (10.49)
                                  P 1   A s F y
                                  P 2   0.85 f c  A c          (10.50)
                                           2
                                      2
           where A   effective concrete area, in (mm )
                 c
                f   28-day compressive strength of concrete, ksi (MPa)
                 c
                                        2
                                            2
                A   total area of steel section, in (mm )
                 s
                F   steel yield strength, ksi (MPa)
                 y
             The number of connectors required between points of maximum positive
           moment and points of adjacent maximum negative moment should equal or
           exceed N , given by
                  2
                                  N 2    P   P 3               (10.51)
                                         S u
             At points of maximum negative moments, the force in the slab P , is com-
                                                             3
           puted from
                                    P 3   A sr F yr            (10.52)
                                                              2
                                                                   2
           where A   area of longitudinal reinforcing within effective flange, in (mm );
                 sr
           and F   reinforcing steel yield strength, ksi (MPa).
               yr
           Ultimate Shear Strength of Connectors in Bridges
           For channels,
                                          t
                              S u   17.4 h    w f c            (10.53)
                                          2
           where h   average channel-flange thickness, in (mm)
                t   channel-web thickness, in (mm)
                w   channel length, in (mm)
             For welded studs (H/d   4 in (101.6 mm),
                                        2
                                 S u   0.4d 2 f c  E c         (10.54)


           ALLOWABLE-STRESS DESIGN FOR SHEAR IN BRIDGES

           Based on the AASHTO specification for highway bridges, the allowable shear
           stress, ksi (MPa), may be computed from
                                      F y   F y
                                 F v    C                      (10.55)
                                      3      3
   324   325   326   327   328   329   330   331   332   333   334