ABOVE-GRADE WATERPROOFING  3.49

























                         FIGURE 3.29 Deck-coating details for plywood deck applications. (Courtesy of General Polymers)



























                         FIGURE 3.30 Typical penetration detail for deck coatings. (Courtesy of Carlisle Corporation)


                            All vertical abutments and penetrations should be treated by installing a sealant cove,
                         followed by a detail coat of nonflow material (Figs. 3.32, 3.33, and 3.34). If a joint occurs
                         between changes in plane such as wall-to-floor joints, an additional detail coat is added or
                         reinforcement. Figures 3.35 and 3.36 show typical installation procedures for this work.
                            With new construction, detail coats of base coat membrane are turned up behind the
                         facing material (e.g., brick cavity wall), followed by coating and detailing to the facing
                         material. This allows for double protection in these critical envelope details. At doors or