Page 367 - Construction Waterproofing Handbook
P. 367

REMEDIAL WATERPROOFING  8.27
                            Grout material is supplied in low-viscosity formulations to enhance its penetrating
                         capabilities. However, unlike epoxy, substrates do not need to be dry for grout application.
                         In fact substrates should be wetted before application and, if necessary, grout can be
                         applied directly into actively leaking joints.
                            Grouts are typically used for concrete or masonry substrates, although they will bond
                         to metals, wood, and polyvinyl chlorides such as PVC piping. Some grouts are also avail-
                         able in gel form, which is used to stabilize soils in areas of bulkheads or soil banks of






































                                        FIGURE 8.24 Two-component injection mixer and injection
                                        equipment. (Courtesy of Webac)














                                         FIGURE 8.25 Hand-held grout injector. (Courtesy of Webac)