Page 789 - Corrosion Engineering Principles and Practice
P. 789

738   I n d e x                                                       I n d e x    739


                      Hot-dip galvanizing, 630      Impressed current cathodic protection
                      HSI (high-silicon iron), 557     (ICCP) (Cont.):
                      HSI anodes, 558                 of ships, 68
                      HSLA (high-strength low-alloy,   in soils, 536–537
                         weathering steel), 372       in water, 529–532
                      Hugel, 113                    Impurities, of environment, 211–213
                      Hulot, M., 55                 Incoloy, 378
                      Humidifying (bubble) towers, 471  Inconel, 200, 686
                      Humidity, 338–339             India, corrosion in, 365, 367
                      Humidity tests, 471           Indirect inspection:
                      HVOF (high-velocity oxy-fuel), 633  for ECDA, 513–514
                      Hydrated magnetite, 19          for ICDA, 516–517
                      Hydraulic cement, 623–624     Indoor atmospheric corrosion, 333–334
                      Hydrogen:                     Industrial atmospheric corrosion,
                        and alkalinity, 28–29          330, 401
                        atomic, 397                 Infrastructure, 15
                        and color, 250–251          Inhibit gates, 498
                        generating, in laboratory, 31  In-line inspection (ILI, smart pigs,
                        nascent, 397                   intelligent pigs), 518–522
                        power of, 29                  crack detection tools, 521–522
                        and soils corrosion, 397      decision tree for, 464
                      Hydrogen blistering, 184        geometry tools, 522
                      Hydrogen sulfide, 273           and magnetic flux leakage, 519
                      Hydrogenase assays, 419         metal loss tools, 520–521
                      Hydrogen-induced cracking (HIC),   and transmission pipelines, 518–522
                         183–184                      (See also specific types, e.g.: Magnetic
                      Hydroscope (see Remote field       flux leakage)
                         inspection)                Inorganic binders, 612–613
                      Hydrostatic testing, 518      Inorganic (nonmetallic) coatings, 587,
                      Hydrothermal sealing, 141, 142   623–627
                      Hydrotreating, 693              anodizing of, 625
                      Hydrous ferrous oxide, 19       and cementation, 627
                      Hydroxyl:                       ceramics, 624–625
                        and alkalinity, 28            chromate filming, 626
                        and cathodic reactions, 250–251  glass, 624–625
                                                      hydraulic cement, 623–624
                           I                          and nitriding, 626
                                                      passive films, 626–627
                      IBED (ion beam enhanced         phophatizing of, 625–626
                         deposition), 634           Inorganic zinc coatings, 600, 607
                      ICCP (see Impressed current cathodic   Inspection:
                         protection)                  of coatings, 638–647
                      ICDA (see Internal corrosion damage   ultrasonic, 151, 153
                         assessment)                Institute for Safety Analysis (TISA), 341
                      ILI (see In-line inspection)  Insulation, thermal, 399
                      Immunity region, 79           Intelligent pigs (see In-line inspection)
                      Impact echo/spectral analysis, 267  Intercrystalline (intergranular)
                      Impingement, 453                 cracking, 195
                      Impressed current cathodic protection   Intergranular corrosion, 160, 161,
                         (ICCP), 556–561               180–181
                        and anode backfill, 540–543  Intergranular (intercrystalline)
                        and anode beds, 538–540        cracking, 195
                        boundary element methods for, 578  Intermediate (secondary) coatings, 609
                        for concrete, 545–547       Internal corrosion damage assessment
                        consumable anodes, 556–557     (ICDA), 515–518
                        and corrosion cells, 397      details examination, 517–518
                        interference problems with, 401  indirect inspection, 516–517
                        modeling for, 579–582         postassessment, 517–518
                        nonconsumable anodes, 559–561  preassessment, 515–516
                        protection with, 134          and transmission pipelines, 515–518
                        semiconsumable anodes, 557–559
   784   785   786   787   788   789   790   791   792   793   794