3.22                      CHAPTER THREE

             TABLE 3.8    Protection of Steel reinforcement (MSJC-08 Code Section 1.15.4, [3.2])

                         Condition          Bar size   Required cover, in.
             Masonry face exposed to    Larger than No. 5   2
               earth or weather   No. 5 and smaller    1½
             Masonry not exposed to    All sizes       1½
               earth or weather

         shell, mortar, and grout surrounding the bar. At bed joints, cover includes total thickness
         of mortar and grout from the exterior of the mortar joint surface to the nearest surface of
         steel. Table 3.8 presents mandatory code requirements for the protection to steel reinforc-
         ing bars [3.2].


         3.7 MODULUS OF ELASTICITY
         OF MASONRY MATERIALS

         3.7.1  Modulus of Elasticity of Steel Reinforcement
         The value of the modulus of elasticity of steel, E , is commonly taken as 29,000 ksi (MSJC-
                                           s
         08 Code Section. 1.8.2.1, [3.2]).

         3.7.2  Modulus of Elasticity of Masonry
         The value of the modulus of elasticity of masonry, E , has been found to be dependent on
                                              m
         the 28-day compressive strength of masonry (f′). This relationship is analogous to the modu-
                                         m
         lus of elasticity of concrete which depends on the 28-day compressive strength of concrete.
         Accordingly, the values of modulus of elasticity of masonry are expressed as a function of the
         28-day compressive strength of masonry prism as follows [MSJC-08 Code Section 1.8.2.2]:
                                 Clay masonry: E  = 700 f′ m          (3.1)
                                             m
                              Concrete masonry: E  = 900 f′ m         (3.2)
                                             m
           The above values of the moduli of elasticity are carryover from 1999 and 2002 MSJC
         Codes. In earlier masonry codes, the value of modulus of elasticity was specified as 1000 f′.
                                                                        m
         Research has indicated a large variation in the relationship between the compressive
         strength of masonry and the modulus of elasticity [3.39, 3.40], and values of modulus of

         elasticity lower than 1000 f′ may be more typical. Values of E  given by Eqs. (3.1) and (3.2)
                            m
                                                    m
         are higher than indicated by the best fit of data relating the modulus of elasticity of masonry
         to the compressive strength of masonry. This is justified in view of the fact that actual
         compressive strength of masonry significantly exceeds the specified compressive strength,
         particularly for clay masonry. Readers should refer to Commentary ([3.4] Section 1.2) for
         a discussion on this topic.
           Users of some of the earlier design codes such as 1997-UBC [3.41] would note that
         the aforestated values of the modulus of elasticity of masonry are different than those in
         1997-UBC, which specified the same value for both clay and concrete masonry, given by
                                             6
         Eq. (3.3) and its maximum value limited to 3 × 10  psi:
                                     E  = 750 f′ m                    (3.3)
                                      m