Page 434 - Design of Reinforced Masonry Structures
P. 434

6.84                       CHAPTER SIX

           Problems
           6.1  A 16 ft high, 8 in. nominal, solid grouted, concrete masonry wall is centrally rein-
               forced with No. 6 vertical bars (Grade 60) spaced horizontally at 24 in. on center.
                                 2
               The wall weighs 78 lb/ft  per linear foot of wall. It carries a superimposed dead
               roof load of 150 lb/ft and a roof live load of 80 lb/ft length of the wall. The roof
               is supported on a ledger beam attached to the wall, which creates an eccentricity
               of 4 in. from the center line of the wall (Fig. P6.1). The lateral load due to wind is
                    2
                                            2
               20 lb/ft  and due to earthquake is 42 lb/ft . Check the adequacy of the wall to carry
                                                       2
               gravity and lateral loads, and deflection.  ′ f  = 1800 lb/in. .
                                             m
                                          D = 150 lb/ft
                                          Lr = 80 lb/ft
                                         e = 4"  Roof
                                               Ledger
                                               beam
                         Lateral loads
                                             4" Nominal
                                             CMU wall
                         Wind: 20 pst
                                                      16' – 8"
                                             #6 @ 24" o.c.
                        Seismic: 42 pst      vertical bars





                        FIGURE P6.1
           6.2  A 24 ft high, 8 in. nominal, solid grouted, concrete masonry wall is to be designed
                                                 2
               to resist out-of-plane load due to wind = 20 lb/ft  and due to earthquake = 42 lb/ft   2
                                  2
               (Fig. P6.2). It weighs 84 lb/ft  per linear foot and carries a superimposed dead roof load
               of 350 lb/ft and a roof live load of 240 lb/ft length of the wall. The roof is supported on
               a ledger beam attached to the wall, which creates an eccentricity of 4 in. from the center
               line of the wall. Determine the reinforcement (Grade 60) requirements for this wall.
               Assume that the wall is classified as Seismic Design Category D and  ′ f  = 2500 lb/in. . 2
                                                              m
                                           D = 350 lb/ft
                                           Lr = 240 lb/ft
                                          e = 4"  Roof

                                                Ledger
                                                beam
                          Lateral loads
                                               As = ?
                          Wind: 20 pst
                                                       24'
                                               8" nominal
                         Seismic: 42 pst       CMU wall






                         FIGURE P6.2
   429   430   431   432   433   434   435   436   437   438   439