Page 166 - Design of Solar Thermal Power Plants
P. 166

3.3 THERMAL PERFORMANCE OF PARABOLIC TROUGH COLLECTOR  151

           TABLE 3.3 Measured Values of Heat Loss Coefficient of SCHOTT PTR70
                      Evacuated Tube [22]

                                                      Evacuated
                   Evacuated              Mean        Tube and
                   Tube       Mean Glass  Ambient Air  Ambient Air  Heat Loss
                   Temperature/  Temperature/  Temperature/  Temperature  Coefficient

           Testing  C          C           C          Difference/ C  HL/(W/m)
           1       100        26          23           77          15
           2       153        30          23          130          23
           3       213        35          23          190          43
           4       246        38          24          222          59
           5       317        50          24          293         113
           6       346        55          23          323         141
           7       390        65          24          366         204
           8       418        73          25          393         257
           9       453        82          23          430         333
           10      458        84          24          434         348
           11      506        99          24          482         495




























           FIGURE 3.20  Heat loss coefficient of PTR70 evacuated tube from schott of germany [22].
           Data Source: Technical Report NREL/TP-550-45633, May 2009.
   161   162   163   164   165   166   167   168   169   170   171