Page 220 - Design of Solar Thermal Power Plants
P. 220

3.7 CALCULATION OF ANNUAL POWER GENERATION     203


                                                 1
                                     350°C
                                                           Auxiliary
                                                           heater
                                  9
                                 a                   c   12    13
                                         Hot    Cold         d
                                         tank   tank
                            2
                                                    240°C          1500 kW
                                 10                       Generator
                                                                    Steam
                    Receiver                           11           turbine
                                    By-pass valve
                                              Saturated steam         3
                                                            6
                            Auxiliary
                             boiler                         Water    Condenser
                                         b                  replenishing
                                    Steam thermal storage   tank       4
           Heliostat                                Deaerator            pump  Condensate
                        tower       8          7                   5
              field
                                    Feed pump
           FIGURE 3.48  Principle thermal system of Badaling power plant (numbers in the figure
           refer to serial number of flow passage).





                                  X  b
               Type15-2  CenRec   X2H     THROTTLE   Stage          Stage-2
                                                             P
                    FEffMatx
                                                             S-split  ElecGe_2
                                                    Type121b
                                         turbcontrol
                              Equa
                                                                   Condens
           Tank Temperature
                     Equa-2              Type5b    Type5b-2
                                                                    Type3d-2

            Tank Pressure              Type3d
                                                        Deaerator
                      Type24

             Tank Flowrate             Equa-3                       Type65d



              Type25d     Type25d-2  Type25d-3  Type25f  Type25d-5  Type25d-4
              FIGURE 3.49  Full system simulation TRNSYS model of Badaling power plant.