Page 202 - Dynamics and Control of Nuclear Reactors
P. 202

200    CHAPTER 14 Pressurized heavy water reactors




                            1.0045

                             1.004
                            1.0035

                           zone 1 power (FPU)  1.0025
                             1.003


                             1.002

                            1.0015

                             1.001
                            1.0005

                                1
                                 0          5          10          15          20         25
                                                           time (h)
                         FIG. 14.5
                         Power variation in zone 1 due to ramp reactivity insertion in zone 1: FPU: Full Power Unit.
                         Used with permission from Nuclear Technology, Francis & Taylor (H. Javidnia, J. Jiang, M. Borairi, Modeling and
                         simulation of a CANDU reactor for control system design and analysis, Nucl. Technol. 165 (2) (2009) 174–189).

                            1.0002
                                                                                     zone 2
                                                                                     zone 3
                            1.0001                                                   zone 4
                                                                                     zone 5
                                                                                     zone 6
                                1                                                    zone 7
                           zonal powers (FPU)  0.9999




                            0.9998

                            0.9997


                            0.9996

                            0.9995
                                 0          5           10         15          20         25
                                                            time (h)
                         FIG. 14.6
                         Power variation in zones 2-7 due to ramp reactivity insertion in zone 1. FPU: Full Power Unit.
                         Used with permission from Nuclear Technology, Francis & Taylor (H. Javidnia, J. Jiang, M. Borairi, Modeling and
                         simulation of a CANDU reactor for control system design and analysis, Nucl. Technol. 165 (2) (2009) 174–189).
   197   198   199   200   201   202   203   204   205   206   207