Page 203 - Estimators Piping Man Hour Manual
P. 203

186    Section  Four—MECHANICAL INSTRUMENTATION

                 PNEUMATIC      LIQUID   LEVEL   TRANSMITTERS


                                    Local  Mounted


                                  MAN HOURS EACH


                                                                   Man Hours
                                                                     Each
        LT Liquid Level Transmitter, Pneumatic, D/P Cell. Foxboro Model:
        15FA1. Range Capsule: 5-25" water, adjustable  span.  Body & Flange:
        Cadmium-plated carbon  steel. Process Connection:  High pressure-
        ANSI raised face modified  flange;  Low pressure -  k» NPT.  Flange:
        6"; 150-lb with 5" flange extension. Output Signal: 3-15 psi.
        Mounting: By flange process connection.  With air  filter-regulator  set.
        LT Liquid  Level Transmitter, Pneumatic, D/P Cell. Foxboro Model:
        13FA1. Range Capsule: 20-205" water or 200-850" water,  adjustable
        span.  Body & Flange: Cadmium-plated carbon steel. Process
        Connection: High pressure-ANSI  raised face modified flange;
        Low pressure -  /£ NPT. Flange: 3"; 150-lb with 5"  flange  extension.
        Output Signal:  3-15  psi. Mounting: By flange process connection.
        With air  filter-regulator  set.


      Above man hours include checking out of storage, calibrating, hauling to erection site, installing, testing and final
      checking of the level transmitters or controllers complete with air supply filter-regulator, supply, and output gauges.
      Man hours do not include installation of air supply and air signal lines or bolt-up of flanges. See other piping
      accounts for these man hours.
   198   199   200   201   202   203   204   205   206   207   208