Page 87 - Estimators Piping Man Hour Manual
P. 87

7O   Section One-SHOP FABRICATION

                  TESTING FABRICATED ASSEMBLIES
                   Hydrostatic Testing of Plain or Beveled Ends Only

                                  Carbon Steel Material
                            For Pressures Not Exceeding 4,000 P.S.I.


                               NET MAN HOURS PER END
                Standard  Extra Hvy.
        Pipe     Pipe&     Pipe&               SCHEDULE NUMBERS
         Size   O.D. Sizes  O.D. Sizes
        Inches  3/8" Thick  1/2" Thick  20  30  40  60  80  100  120  140  160

       2 "or Less  2.5       2.8    --   --  2.5  -    2.8  ..   -    --  4.4
       2-1/2"      2.6       3.1    --   --  2.6  -    3.1  --   --   -   5.0
        3          3.0       3.4    --   --  3.0  -    3.4  --   „    „   5.6
       4           3.5       4.2    --   --  3.5  --   4.2  --   5.7  --  6.4
       5           3.9       4.6    ..   --  3.9  --   4.6  --   6.2  „   7.4
        6          4.4       5.1    --   --  4.4  --   5.1  --   7.0  --  8.4

        8          4.9       5.8    4.9  4.9  4.9  5.3  5.8  7.0  8.2  9.2  10.1
        10         5.5       6.3    5.5  5.1  5.5  6.3  7.3  8.7  9.8  11.2  12.5
        12         6.1       7.0    6.1  6.1  6.7  7.9  9.5  10.9  12.2  13.7  15.6
        14 O.D.    6.8       7.8    6.8  6.8  7.4  9.0  11.0  12.4  14.0  16.2  18.9
        16O.D.     7.8       8.8    7.8  7.8  8.8  11.1  13.4  15.4  17.3  20.4  23.9
        18 O.D.    9.1      10.4    9.1  9.8  11.5  13.7  16.9  19.2  21.9  25.1  29.3
        20 O.D.   10.1      11.9   10.1  11.9  14.0  16.9  20.6  23.8  26.9  30.7  36.2
        24 O.D.   13.5      15.4   13.5  15,6  20.6  25.1  31.3  35.8  41.1  47.3  54.3

     Above man hours are for plain or beveled ends only. See preceding table for flanged ends.

     Man hours are for a maximum holding time of one hour at test pressure.
   82   83   84   85   86   87   88   89   90   91   92