Page 355 - Failure Analysis Case Studies II
P. 355

340


























                        Fig. 9. Cr distribution map of crack tip region (same location as shown in Fig. 6(b))




           steel, excessive oxidation can occur in a short period if the operation temperature is higher than
           1090°C [4].
             In order to know whether the failed radiant tubes had been in service below or above 1000°C,
          the degradation level of the microstructure due to thermal aging was assessed. In most of the cases,
          the service temperature of the tube can be predicted  by comparing the microstructure with that
          under  known  service conditions.  Figure  10 shows  a  typical  microstructure  of  the  failed tube.



























                                          IWF-
                             Fig. 10. Microstructure of uncracked region of the tested radiant tube.
   350   351   352   353   354   355   356   357   358   359   360