Unit Monitoring and Control  173

 Regenerator dilute phase catalyst level      = 27.0 ft/8.2 m
 Regenerator dense phase catalyst bed level   = 15.0 ft/4.6 m
                                                       3        3
 Catalyst density in the regenerator dense phase  = 25 Ib/ft /400 kg/m
 Regenerated catalyst standpipe elevation     = 30.0 ft/9.1 m
 Pressure above the regenerated catalyst slide valve  = 30.5 psig/210.3 K p
 Regenerated catalyst slide valve AP (@ 30% opening) = 5.5 psi/37.9 K p
 Reactor-regenerator pressure AP              =3. 0 psi/20.7 K p


 Also, see Figure 5-9 for a graphical representation of the preliminary
 results.
  Starting with the reactor dilute pressure as the working point, the
 pressure head corresponding to 25 feet (7.6 m) of dilute catalyst
 fines is:

                  3       2      2
  (25 ft) x (0.6 lb/ft ) x (1 ft /!44 in ) = 0.1 psig (0.7 K p)

 Therefore, the pressure at the top of the stripper bed is:

  19.0 + 0.1 = 19.1 psig (131.7 K p)

 The static-pressure head in the stripper is:

                 3              2
  (18 ft) x (40 lb/ft ) x (1 ft/144 in ) = 5.0 psig (34.5 K p)
 The pressure above the spent catalyst standpipe is:

  19.1 + 5.0 = 24.1 psig (166.2 K p)

 The pressure buildup in the spent catalyst standpipe is:

  26.1 - 24.1 =2 psi (13.8 K p)


 The pressure below the spent catalyst slide valve is:

  26.1 -4.0 = 22.1 psig (152 K p)

 The pressure head corresponding to 28 feet (8.5 m) of dilute catalyst
 fines in the regenerator is:

                               2
                3
                        2
  (28 ft) x (1 lb/ft ) x (1 ft /144 in ) = 0.2 psig (1.4 K p)