PUMPS    125

                & Note: Pumps handling hydrocarbons can tolerate       ➢ The motor is usually tripped or not allowed to start
                  lower flows than cold water, as specific volume of       under these conditions. Similarly, low-flow
                  water is much higher than that for hydrocarbons, (cf.  switches on the discharge are used to alarm and
                  see cavitation issues).                                trip the motor when a low-flow condition has
              . What is the significance of the minimum flow required      occurred.
                by a pump?                                             ➢ This interlock is often bypassed (manually or with
                & Centrifugal pumps have a required minimum flow          a timer) during pump start-up to allow the flow to
                  below which severe operational problems and dam-       reach its normal operating point, at which time the
                  age can occur. Below minimum flow, pump may             bypass is removed. Changing from switches to
                  cavitate drawing air into its suction. Its casing gets  transmitters for increased accuracy and easier
                  filled and looses its prime.                            failure diagnosis is presently favored.
              . What are design requirements to handle minimum flows  . For a given size of already installed pump motor, how is
                in a centrifugal pump system?                       the maximum possible size of an impeller in the pump
                                                                    casing decided?
                & If the primary pump discharge path can be blocked, a
                  recirculation line is required to accommodate the  1. Place pump discharge control valve in wide-open
                  minimum flow of the pump. Such lines can be           position.
                  designed either for continuous or for controlled  2. Measure the amperage drawn by the pump?
                  flows.
                                                                    3. Determine maximum possible impeller size that can
                  ➢ Continuous flows are more common in smaller
                                                                       be used with the existing motor, using the relation-
                    pumps and use a flow restriction orifice in the
                                                                       ship
                    recirculation line to bleed off the pressure gained
                    from the pump.                                                              1=3
                                                                                    d 2 ¼ d 1 ½A r =A 1 Š  ð5:19Þ
                  ➢ Controlled flows are normally used in higher
                    capacity systems where a continuous, minimum       where A r is the rated capacity of the motor in amperes
                    flow would lead to significantly higher operating    (service factor, which is 10–15% of the rated capac-
                    costs or the selection of a larger pump. Con-      ity); A 1 is the actual amperage as measured under
                    trolled flows are most often accomplished with a    step 2; and d 1 is the existing impeller diameter.
                    self-regulated pressure control valve on the
                    pump discharge or a flow control valve and      . Which of the following two arrangements in the control
                    controller with the minimum flow configured       of centrifugal pumps involves better energy conserva-
                    as the set point.                               tion?: Throttling the flow with a valve on pump dis-
                & Excess pumping energy increases the temperature of  charge or using a variable speed control on the pump
                  the fluid being pumped. Generally, the temperature  drive?
                  rise is negligible, except when the pump is operating  & Using a variable speed control conserves energy
                  near shutoff.                                        better. It is used when flow rates are large to justify
                  ➢ For this reason, the minimum flow recirculation     additional costs in installing variable speed control.
                    lineshouldbeplaced insucha waythatthe            & For low flow capacities, throttling is cheaper.
                    outlet of the line connects to a vessel instead of  . What are the additional requirements for the following
                    the pump suction line, thus giving the fluid     pump options?
                    time to shed its excess heat. If the fluid is added  & Table 5.2 lists the additional requirements for differ-
                    to the suction line, the temperature increase will  ent pump options.
                    not be dissipated. A small heat exchanger may
                                                                   . “Centrifugal pumps are used as metering pumps.” True/
                    be placed ahead of the pump suction to achieve
                                                                    False?
                    the same result for relatively high head pumps
                                                                     & False.
                    ( 150 m) or when handling heat-sensitive
                    fluids.                                         . Under what circumstances use of inducers is desirable
                                                                    on pump inlet?
                  ➢ Low suction pressure switches interlocked into the
                                                                     & Inducers are used to improve pump suction
                    plant control system sometimes trip the pump or
                    prevent its start-up when the suction pressure is  conditions.
                    below a set value. High-pressure switches can be  & Inducers improve NPSH requirements for difficult
                    installed on the pump discharge so as not to exceed  applications.
                    the maximum allowable output pressure.           & They assist flow of viscous fluids into pump casing.