5.10               ENGINEERING RESPONSE TO FAILURES

             xxx  SEGMENT SERIAL NUMBER     SITU  REMAINED ATTACHED TO FOUNDATION
                                                  AT COLLAPSE SITE
             xxx  TENTATIVE SEGMENT LOCATION
                                            NBS X  SEGMENT REMOVED BY NBS
                 SEGMENT(S) NOT FOUND

            6th Floor
            EL.52'-4"                                        116     247
                                      184     378     066
            5th                                              098
            EL.43'-8"         503

                                                             095
            4th                               380                    222
            EL.35'-0"                 175
                                                      040
            3rd
                                                                     097
            EL.26'-4"                         384
                                                             174
            2nd                                       058              291
            EL.17'-8"
                                      022
                              139             379
            1st Floor
                                                      068    134     124
            EL.9'-0"
                              128                       065
            Grd                                         NBS
            EL.0'-0"
                                                      061
                              158             377
                                                                     126
                                      177
            C                                         060    466
            EL.– –10'-0"

            D                                                        327
              –
            EL.–18'-8"                        419
                                                      393
            E                                 SITU           SITU
            EL.– –27'-4"
                                                        BASE
            COLUMN
            DESIGNATION       1-E     2-E     3-E    3.8-E  4.8-E   6-E.5
           FIGURE 5.7  For the investigation of the 1987 collapse of the L’Ambiance Plaza, a comprehensive serial
           piece-mark system, in combination with identity marks and match marks, allowed almost complete recon-
           struction of the columns, leading to a persuasive determination of the collapse cause, which differed from
           the theory proposed by OSHA.