Page 257 - Formulas and Calculations for Petroleum Engineering
P. 257

250 Formulas and calculations for petroleum engineering



              4.101 Volume capacity of pipe

              Input(s)
                 D i :  Inner Diameter of Pipe (in.)
                 L:  Length of Pipe (ft)


              Output(s)

                 V:   Volume Capacity of Pipe (bbl)


              Formula(s)

                                                                   2
                                                         0:7854   D   L
                                                                   i
                                                      V ¼
                                                              808:5
              Reference: Samuel. E Robello. 501 Solved Problems and Calculations for Drilling Operations. Sigma Quadrant. 2015.
              Houston, Texas, Page: 44.



              4.102 Volume of fluid loss per unit area measured in a dynamic test (acidizing)
              Input(s)
                 t:  Time (s)
                                            2
                                         3
                 V spt :  The Spurt Volume (m /m )
                 v N :  Fluid Loss Velocity (m/s)

              Output(s)
                                                         2
                                                      3
                 V:  Volume of Fluid Loss per Unit Ares (m /m )

              Formula(s)

                                                         V ¼ V  + v t
                                                              spt  N

              Reference: Williams, B. B., Gidley, J. L., & Schechter, R. S. (1979). Acidizing fundamentals. Henry L. Doherty Memorial
              Fund of AIME, Society of Petroleum Engineers of AIME, Page: 42.



              4.103 Volume of fluid loss per unit area measured in a static test (acidizing)
              Input(s)
                                             1/2
                 C w :  Fluid Loss Coefficient, (m/s )
                 p ffiffi            1/2
                  t:  Time root (s )
                                            2
                                         3
                 V spt :  The Spurt Volume (m /m )
              Output(s)
                                                      3
                                                         2
                 V:  Volume of Fluid Loss per Unit Ares (m /m )
   252   253   254   255   256   257   258   259   260   261   262