Page 60 - Fundamentals of Magnetic Thermonuclear Reactor Design
P. 60

ITER – International Thermonuclear Experimental Reactor  Chapter | 3    43




               TABLE 3.1 Main Design Parameters of the ITER Reactor
               Parameters
               Fusion power (MW) at long-pulse scenario    500
               Short-pulse scenario                        700
               Major radius (m)                            6.2
               Minor radius (m)                            2.0
               Q factor  a                                 ≥10
                                         2
               Average neutron wall loading (MW/m )        >0.5
               Induction pulse duration (s)                450
               Stability margin                            3
               Toroidal magnetic field maximum (T)         11.8
                           3
               Plasma volume (m )                          816
                                    2
               Plasma column surface area (m )             680
               a The ratio of fusion power to additional heating power.





               TABLE 3.2 ITER Parameters Designed for the D–T Campaign

                                                   Working cycle scenario
               Parameters                   Inductive  Hybrid   Non-inductive
               Fusion power (MW)            500        400      356
               Q factor                     10.0       5.4      6.0
               Total plasma heating power (MW),  151   154      130
               of which additional heating power   50  73       59
               (MW)
               Plasma thermal energy (MJ)   353        310      287
               Aspect ratio                 6.2/2.0    6.2/2.0  6.35/1.85
               Discharge current (MA)       15.0       13.8     9.0
               Toroidal magnetic field on the plasma   5.3  5.3  5.18
               column axis (T)
               Working cycle duration (s)   450        1,000    3,000
               Minimum cycle repetition time (s)  1,800  4,000  12,000
                                    3
               Maximum D–T flow rate (Pa m /s)  200    160      120
   55   56   57   58   59   60   61   62   63   64   65