Page 159 - Handbook of Civil Engineering Calculations, Second Edition
P. 159

1.142           STRUCTURAL STEEL ENGINEERING AND DESIGN






















                             FIGURE 37






                            The case of no-stiffeners corresponds to k   5.
                            2. Check the original assumptions for doubling the shear strength
                            To double the shear strength, I k   2   5   10. Then in AISC Eq. A-G3-4,
                                                            5
                                                    k   5 +       10
                                                           (a/h) 2
                            This implies a/h   1.0 or a   k; thus, the clear distance between transverse web stiffeners
                            a   h   56 in. (142.2 cm). Checking the original assumption we obtain


                                    h    56 in.              k        10
                                                128.9 >  234        234      123.3    o.k.
                                   
 t w  0.44 in.           F y      36
                            3. Design the stiffener, trying a pair of stiffener plates
                            Stiffener design can be performed thusly. Because tension field action is not utilized, the
                                        3
                            equation I st   at w j must be satisfied, where
                                                        2.5
                                                    j        – 2   0.5
                                                       (a/h) 2
                                                        2.5
                                                     j      – 2   0.5
                                                         1 2
                                                          3
                                                                              4
                                                                      4
                                         I st   56 in.   (0.44 in.)   0.5   2.34 in (97.4 cm )
                            Try a pair of stiffener plates, 2.5 in.   0.25 in. (6.35   0.635 cm), as in Fig. 38. The mo-
                            ment of inertia of the stiffener pair about the web centerline
                                0.25 in. × (5.44 in.) 3
                                                                             4
                                                       4
                                                                                     4
                            I st                 3.35 in. > 2.34 in. 4  o.k. (139.4 cm > 97.4 cm )  o.k.
                                       12
   154   155   156   157   158   159   160   161   162   163   164