head loss is 57.61 ft (17.6 m) of water.


                          TABLE  8  Sample  Calculation  for  Full  Flow  through  Cooling
                     Circuit* (Fittings and Piping in Circuit)























































                  Compute  the  head  loss  for  0,  0.2,  0.4,  0.6,  and  0.8  load  on  the  engine,

               using the same procedure as in steps 1, 2, and 3 above. Plot on the pump
               characteristic curve, Fig. 9, the system head loss for each load. Draw a curve
               A through the points obtained, Fig. 9.

                  Compute the system head loss for condition b with half the jacket water
               [150  gal/min  (9.5  L/s)]  passing  through  the  heat  exchanger  and  half  [150
               gal/min (9.5 L/s)] through the bypass circuit. Make the same calculation for