Page 336 - Handbook of Energy Engineering Calculations
P. 336

P .  For  liquid  heating  systems  using  solar  energy  as  their  heat  source,  the
                 L
               monthly solar fraction is given by





               if P  > P /12 (if not, f  = 0).
                    s
                                         s
                          L
                  For air-based solar heating systems, the monthly solar heating fraction is
               given by





               if P  > 0.07P  (if not, f  = 0).
                               L
                                           s
                    s
                  Flow rate, storage, load heat-exchanger, and domestic hot-water correction
               factors for use in the equations for P  and P , in steps 1 and 2 above, are
                                                              s
                                                                       L
               given in Table 11 and Fig. 11.
   331   332   333   334   335   336   337   338   339   340   341