Page 331 - Handbook of Energy Engineering Calculations
P. 331

Calculation Procedure



               1. Determine the solar parameter P
                                                           s
               The F chart is a common calculation procedure used in the United States to
               ascertain the useful energy delivery of active solar heating systems. The F

               chart applies only to the specific system designs of the type shown in Fig. 8
               for  liquid  systems  and  Fig.  9  for  air  systems.  Both  systems  find  wide  use
               today.