Page 330 - Handbook of Energy Engineering Calculations
P. 330

Bismarck, ND, and the following specifications apply:


                  Building
                  Location: 47°N latitude
                                                                                   2
                  Space-heating load: 15,000 Btu/(°F · day) [8.5 kW/(m  · K · day)]

                  Solar System
                                                                                                   2
                                                                              2
                  Collector loss coefficient: F U  = 0.80 Btu/(h · ft  · °F) [4.5 W/(m  · K)]
                                                    R C
                  Collector optical efficiency (average):


                  Collector tilt: β = L + 15° = 62°
                                                             2
                                                  2
                  Collector area: A  = 600 ft  (55.7 m )
                                       c
                                                                               2
                  Collector fluid flow rate:        c /A  = 11.4 lb/(h · ft  (water) [0.0155 kg/(s ·
                                                                              c
                                                        c
                  2
               m )]
                  Collector fluid heat capacity—specific gravity product: c  = 0.9 Btu/(lb ·
                                                                                        pc
               °F) [3.8 kJ/(kg · K)] (antifreeze)
                                                     2
                                                                            2
                  Storage capacity: 1.85 gal/ft (water) (75.4 L/m )
                                                    c
                                                                                                     2
                                                                       2
                  Storage fluid flow rate:  /A   = 20 lb/(h · ft )(water)[0.027 kg/(s · m )]
                                                 s
                                                     c
                  Storage fluid heat capacity: c  = 1 Btu/(lb · °F)(water) [4.2 kJ/(kg · K)]
                                                     ps
                  Heat-exchanger effectiveness: 0.75
                  Climatic Data
                  Climatic data from the NWS are tabulated in Table 5.



                          TABLE 5 Climatic and Solar Data for Bismarck, North Dakota