FIGURE 1b T-S diagram corresponding to Fig. 1a.



               Calculation Procedure:



               1. Analyze the conditions in the evaporator
               Use the low-temperature steam data (in SI units) from “Thermodynamic and
               Transport  Properties  of  Steam,”  The  American  Society  of  Mechanical
               Engineers, 1967, or later editions, for steam temperature, pressure, specific

               volume, enthalpy, and entropy.
                  The evaporator









               Therefore
                                                  x  = 0.00344, or 0.344%
                                                   2

               2. Find the actual turbine work output
               Warm-water mass-flow rate per unit turbine mass-flow rate