Design of Connections for Axial, Moment, and Shear Forces
Design of Connections for Axial, Moment, and Shear Forces 69
For tension, the bolts and end plate are checked together for pry-
ing action.
Since all of the bolts are subjected to tension simultaneously,
there is interaction between tension and shear. The reduced ten-
sile capacity is
170>14
B 5 r t 5 1.13 3 64 a1 2 b 5 29.1 kips/bolt
20.3
Since 29.1 kips > 218/14 15.7 kips, the bolts are ok for tension.
The bearing type interaction expression would also be checked if
the serviceability slip-critical limit state were used. Prying action
is now checked using the method and notation of the AISC Manual
of Steel Construction (2005), pages 9-10 through 9-13:
5.5 2 0.47
b 5 5 2.52
2
8.5 2 5.5
a 5 5 1.50
2
Check 1.25b 1.25 2.52 3.15. Since 3.15 > 1.50, use a 1.50.
1.0
br 5 2.52 2 5 2.02
2
1.0
ar 5 1.50 1 5 2.00
2
1.01
1.25
5 1 2 5 0.583
3
4.44 3 29.1 3 2.02
t 5 5 1.22
c
B 3 3 58
1 1.22 2
5 ca b 2 1d 5 1.40
0.583 3 2.01 0.75
Use 1.00
The design strength per bolt including prying is
0.75 2
T 5 29.1a b s1 1 0.583 3 1.00d 5 17.4 kips . 17.4 kips, ok
1.22
In addition to the prying check, the end plate should also be
checked for gross shear net shear and block shear. These will not
control in this case.
b. Weld of end plate to beam web: The weld is a double line weld