Page 383 - Improving Machinery Reliability
P. 383

Startup Responsibilities   349






























                                Figure 8-5. Basic tabulation of pertinent pump data.



                    Column 1:    Plot plan or item number.
                    Column 2:    Block or plant area.
                    Column 3:    Manufacturer.
                    Column 4:    Model designation.
                    Column 5:    Manufacturer's  serial number.
                    Column 6:    Train type. It is highly advantageous to produce isometric sketch-
                                 es identifying  the various  train types,  as shown  in  Figure  8-6.
                                 Supervisory personnel can rapidly visualize the relative size and
                                 complexity of machinery trains by referring to these train isomet-
                                 rics. A second variant of these isometrics should be marked up to
                                 define where to install vibration transducers or to show operating
                                 technicians where to take vibration readings.
                    Column  7:   Pumping service designation.
                    Column  8:   Fluid pumped (pumpage).
                    Column  9:   Specific gravity. This information is important when mining
                                 whether the pump is suitable for run-in of water.
                    Column 10:   Pumping temperature.
   378   379   380   381   382   383   384   385   386   387   388