          11.2.5 Case Study

          3D TRASAR Technology for Sugar equipment was installed at a large raw
          sugar mill. The mill faces water scarcity and consequently reuses process
          condensate in its low-pressure boilers. For monitoring the process conden-
          sate quality, an a-naphthol test was done every 15 minutes. In Figure 11.7,
          the performance of the conductivity sensor is shown. The crosses represent
          the a-naphthol data points from the operator logs. The results from the test
          are qualitative and are logged as nil, trace, very faint, and so forth, depend-
          ing upon the color intensity of the ring that develops for the sample under
          test. The a-naphthol test data indicates that there is an entrainment event


































          Figure 11.7 Comparison of sugar fluorometer data, conductivity, and the Molisch test.
          Conductivity shows a poor correlation with sugar concentration.