Page 534 - Industrial Wastewater Treatment, Recycling and Reuse
P. 534

504   Industrial Wastewater Treatment, Recycling, and Reuse


           7. Priming pump
                 The UF permeate is pumped via a priming pump to the
              cartridge filter.
           8. Antiscalent dosing unit
                 During the RO process, dissolved salts are concentrated on the
              reject side as permeate water is being drawn at specific recovery. As
              a result of this arrangement, the dissolved salts concentration increases
              on the reject end, and salts may precipitate if the saturation limit is
              exceeded. As a result, salt scaling (deposition) occurs on the membrane
              surface, leading to inferior performance of the RO system. To prevent
              scaling, an appropriate dose of special antiscalant formulation is
              required. Normally, a 5% concentrated solution of the antiscalant is
              prepared, and dosing pumps in the line introduce about 3–5 mg/L of
              the antiscalant solution into the effluent, as needed.
           9. Cartridge filter
                 The filtered stream then passes through the cartridge filter, which
              arrests any suspended solids that remain.
          10. High pressure pump
                 Exiting the cartridge filter, the clear stream is transported via high
              pressure pumps to the membrane modules for treatment.
          11. Membrane skid
                 The membrane skid consists of membranes mounted in membrane
              housings. The logistics of feeding the effluent through the various mem-
              brane housings depend on the system configuration. Part of the reject
              from the membrane ETP is recycled back due to high pressure pump
              suction, whereas the balance is suitably discharged for further treatment.
          12. RO CIP system
                 A CIP system is provided to clean both RO systems at regular inter-
              vals. The CIP system consists of a tank and pumps.
          13. Permeate tank
                 The permeate coming out of the RO system is collected in this tank.
          14. Decanter centrifuge
                 Excess sludge from the anaerobic and aerobic digestion processes, as
              well as from tube settler I, enters the sludge sump, which then pumps
              the sludge to drying beds.


          13.5.1.6 ML Stream
          13.5.1.6.1 Solvent Stripping System
          As stated above, the ML stream contains mixed solvent traces which need to
          be removed prior to the feed entering the system.