8.6 Velocity to Pressure Transfer  77



           and as the zones are heating the thermocouple will not respond, which will cause
           the controller to keep sending current to the zone. Figure 8.16 shows a nozzle
           with failed heater bands captured in an infrared (IR) image.






















          Figure 8.16  IR thermal image of extended nozzle with heater bands not working.


             ƒ Examine thermocouples for full insertion into thermocouple wells. Also verify
           that heat bands are tight against the barrel. Loose heater bands will have an air
           gap that will restrict heat transfer. See Figure 8.17.



































          Figure 8.17  Nozzle cross section showing fully seated thermocouple.