8.6 Velocity to Pressure Transfer  73


































          Figure 8.11  Velocity to pressure response with cavity pressure: normal response



































                            ®
          Figure 8.12  RJG eDART  graph showing the impact of a poor velocity to pressure transfer.
                    Notice how all of the plotted lines drop down after transfer. This created dimen-
                    sionally unacceptable parts.