Page 89 - Injection Molding Advanced Troubleshooting Guide
P. 89
8.6 Velocity to Pressure Transfer 73
Figure 8.11 Velocity to pressure response with cavity pressure: normal response
®
Figure 8.12 RJG eDART graph showing the impact of a poor velocity to pressure transfer.
Notice how all of the plotted lines drop down after transfer. This created dimen-