         separation  dimension  between  the  coupling  halves.  You'll  need  a
         machinist rule and thickness gauge or feeler gauge to perform a rough
         alignment.

         Before  starting  the  alignment  procedure,  disconnect  the  coupling
         halves. First, veri@  the rough angular alignment inserting feeler gauges
         at  four  points  (90") around  the  faces  between  the  halves.  The
         alignment is correct when  the feeler gauge  distance  is the same at all
         measured points.
         The  rough  parallel  alignment  is  done  by  placing  the  machinist  rule
         across both coupling rim surfaces in the upper position, lower position,
         and both lateral points.  The parallel rough  alignment  is  correct when
         the straight edge rests uniformly on both rims at all four positions.  Be
         sure that  the coupling rims are  concentric with  the pump  and  motor
         shafts.

         Don't  start  the  pump  until  after  completing  all  the  previously
         mentioned  points,  and  any  other  specification  mentioned  in  the
         operation and maintenance manual of the pump provided by the pump
         supplier.  Not  doing  this  could  cause  equipment  damage  and  even
         personal injury. It might even void the pump guarantee.