Know and Understand Centrifugal Pumps


                               €4













                         lncorrrect                       Correct
        Figure 10-11


                Bring the pipe  to the pump  and adjust it to the pump.  Don’t
                adjust the pump to the piping (Figure 10-11).
                To verify pipe strain, place dial indicators on the shaft and watch
                for horizontal and vertical movement. Unite the flanges one at a
                time continually observing the indicator readings. In general the
                indicator  readings  should  not  exceed  0.002  inches  (Figure
                10-12).

         9.  Correct Soft Foot. Soft foot exists when one of the four machinery
             feet is  not  level with  the  base. When  the  base  bolts are  tightened
             with soft foot, the effect can distort and misalign the pump casing.
                To check for soft foot, place a dial indicator onto the machinery
                foot, and loosening the base  bolt. If the indicator moves more
                than  0.002 inches,  the foot is soft and it should be  corrected.
                Go through the same procedure on the remaining feet one at a
                time.