          Install the pump back plate and seal chamber assembly. Mount the dial
          indicator on the shaft and place the needle onto the outer diameter of
          the lip or face of the seal chamber (Figure 14-24). An alternate method
          would  be  to place  the  indicator needle inside  the seal chamber bore.
          Rotate the shaft. This will verify that the shaft is concentric with the seal
          chamber bore. If it is not concentric, the seal may rub against the bore
          when the pump is started.

          With the indicator still in this same position, place the needle onto the
          lip or face of the seal chamber  (Figure 14-25). Rotate the shaft. This